The innovative design of HINKTON Retro-X® enables it to achieve extremely low head
loss. With its ability to make “self - cleaning”, Retro-X® aeration system always operate
at a high - performance level, thus reducing operation and maintenance costs. Retro-X®
the complete answer to low headloss, highly energy efficient fine bubble diffuser in a
wide range of applications in industry and municipal treatment plants.
Retro-X® utilizes an aeration hose with a specially formulated membrane and perforation
technology. Under low airflow conditions, it generates small, slow-rising bubbles, significantly improving oxygen transfer efficiency (≥45%). Its low-resistance design and
adjustable support system enable long-distance airflow transmission. The linear aeration
pattern ensures uniform air distribution and mixing, achieving high oxygen utilization and
energy efficiency. With excellent tear-resistance, oil resistance, and acid/alkali durability,
the system maintains long-term stable performance. In municipal wastewater
applications, it offers a comprehensive service life of over 10 years, and in industrial
wastewater scenarios, its lifespan exceeds 8 years.
Retro-X® aeration system integrated a dedicated control system to enable the
‘self-cleaning’ functionality, ensuring consistent aeration efficiency. The innovation
retrievable installation way enables easy routine inspections and maintenance, significantly enhancing operational convenience.
Main Advantage
·Upgraded Efficiency
The oxygen transfer efficiency is as high as 45% in sewage at a depth of 6 meters. The
bubble rising velocity is less than 0.4m/s, much lower than the conventional 1m/s. Bubbles stays in the water for a long time. It greatly increases oxygen transfer efficiency.
·‘Self - cleaning’ Function
Regular 'self - cleaning ' is carried out to ensure the efficiency of the aeration system
remains stable.
·Low Head Loss
The innovation design of membrane only (no supporting pipe) provides extremely low
head loss.
· Easy Routine Inspections or Aeration Diffuser Replacement
A team of two people can complete the replacement of a set of aeration system in 15
minutes. There is no need to drain water, nor use a crane or any lifting tools.
·Low-cost for Renovation
For the entire aeration system, only the membrane needs to be replaced, while other
pipes and accessories can be recycled.
·Longer Service Life
More than 10 years service life with special membrane material.
Main Design Features
·The innovation design of membrane only (no supporting pipe) provides extremely low
head loss.
·End to end air pathways ensure uniform air distribution.
· Ultra fine bubbles generation. With a bubble average size of 1 mm, the bubbles rise
slowly, which increases the contact area and contact time with the sewage. It turns out
higher oxygen transfer efficiency which reduced air demand, and correspondingly the
energy bill.
·With unique product design and product accessories, HINKTON Retro-X®fine bubble
diffuser revolutionizes the aeration system pipelines and retrievable installation way.
Retrievable Installation
With unique product design and product accessories, HINKTION Retro-X®
revolutionizes the aeration system pipelines and retrievable installation way. When
replacing the aeration tube, it only needs to untie the tension rope and the
quick-installation joint on the air pipe. The aeration pipe can be pulled out from the
bottom of the tank along the stabilizing device, and after replacement, it can be pulled
back to its original position along the rope. It only takes about 15 minutes to complete. The innovation retrievable installation way enables the inspection and maintenance of
aeration pipe with the whole system operate continuously.
Key Characteristics
Retro-X®‘Self-cleaning’Control System
The self-cleaning control system is a standard PLC-based program and component
package integrated into the Retro-X® Unbeatable Aeration System.
The Retro-X® system utilizes PLC programming to control electric valves on distribution
manifolds. Through periodic valve actuation, it modulates or shuts off airflow to specific
manifold zones. By leveraging pressure differentials and valve switching mechanisms,
the system creates airflow pulses that scour the surface of the aeration hoses, removing
biofilm, sludge, or particulate buildup.
This automated self-cleaning process ensures:
• No clogging or fouling on the hose surface.
• Consistent oxygen transfer efficiency (SOTE) and stable head loss over time.
As the core aeration system technology of HINKTON, Retro-X® provides a
more stable, efficient, and easy-to-maintain aeration solution for global
wastewater treatment projects.
It is widely applied in:
• New construction of biochemical systems
• Upgrades and renovations of existing facilities
• Energy-saving retrofits
• Aeration system replacements
This technology delivers reliable performance while optimizing energy
efficiency and simplifying maintenance, making it a leader in advanced
aeration system innovation.
What We can Offer?
· Reliable products tested by hundreds of wwt project.
·Provide product selection suggestions. Our experience in the sewage industry enables
us to better understand customers ' needs. By combining technical requirements with
customers ' actual demands, we put forward comprehensive suggestions to help
customers make better choices.
·Technical support for assistance with aeration system design and calculation.
·Customized services.
·After-sales service feedback within 7 hours.
Case studies
Sichuan Yibin Gaojie Industrial Park II Wastewater Treatment Plant
●Daily Treatment Capacity: 50,000m³/d
●Information: This project involves upgrading the original Cyclic Activated
Sludge System (CASS) process to low dissolved oxygen (DO) process, achieving enhanced discharge standards.
●Process: Bar screens → Primary sedimentation tank → SED biochemical
system → High-efficiency sedimentation tank.
Huaiyuan Economic Development Zone WWT II of Bengbu
●Daily Treatment Capacity: 35,000m³/d
●Information: This project is a newly built wastewater treatment plant
adopting the SED low-dissolved oxygen (DO) process to achieve standard
discharge.
●Process: Pretreatment →SED biochemical system → Tertiary treatment
Acheng Wastewater Treatment Plant, Ordos, Inner Mongolia
●Daily Treatment Capacity: 35,000m³/d
●Information: This project involves upgrading the AAO (Anoxic-Anoxic-Oxic)
process to a low-dissolved oxygen (DO) process, achieving upgraded
discharge standards and expanded capacity.
●Process: Pretreatment →SED biochemical system → Tertiary treatment
Fengcheng Gaoyi Wastewater Treatment Plant of Shijiazhuang
.png)
●Daily Treatment Capacity: 30,000m³/d
●Information: This project involves upgrading the AO (Anoxic-Oxic) process
to a low-dissolved oxygen (DO) process to achieve upgraded discharge
standards.
●Process: Pretreatment →SED biochemical system → Tertiary treatment
Jiangnan New Urban Area Wastewater Treatment Plant, Mudanjiang
●Daily Treatment Capacity: 20,000m³/d
●Information: This project involves upgrading the AO (Anoxic-Oxic) process
to a low-dissolved oxygen (DO) process to achieve upgraded discharge
standards.
●Process: Pretreatment →SED biochemical system → Tertiary treatment
High-Tech Zone Wastewater Treatment Plant, Ulanqab, Inner Mongolia
●Daily Treatment Capacity: 20,000m³/d
●Information: This project involves upgrading the original CASS (Cyclic
Activated Sludge System) process to a low-dissolved oxygen (DO) process to
achieve upgraded discharge standards.
●Process: Bar screens → Primary sedimentation tank → SED biochemical
system → High-efficiency sedimentation tank
DOWNLOAD
since 2012 Co. Reg. No: (1007069-M)
For more information or enquiry, please contact Environmech Sdn. Bhd.
Contact us: http://www.environmech.com/p/contact-us.html Website: www.Environmech.com