Brush Removal & Installation for Electric Self Cleaning Filter supply in Semenyih


Brush Removal & Installation
1. Close the inlet and the outlet line valves.
2. Set the main switch at the control panel to "0" position.
3. Verify that the filter is drained prior to service.
4. Remove the nuts and washers attaching the cover to the filter housing.
5. Remove the cover with the motor assembly.
6. Remove the body seal from the cover groove.
7. Pull the brush assembly out of the fine screen assembly
8. Unscrew the old brushes units from the brush axis.
9. Install the new brush units on the brush axis.
10. Slide the brushes assembly into the fine screen.
11. Verify that the straight side of the body seal fits into the groove located in the cover.
12. Put the cover into its place on the filter. (Take care that the motor's spinning axis housing is
 slid on the brush axis).
13. Install the nuts and washers attaching the cover to the filter housing.
14. Set the main switch at the control panel to "1" position.
15. Open the inlet and outlet line valves.
16. Perform a flushing cycle by pressing the MANUAL FLUSH switch at the control panel.
17. Verify that the hydraulic flushing valves close after a 10 second flushing cycle and FLUSHING
 lamp at the control panel extinguishes.
18. Check for leaks.

WARNING

Take precautions while operating the filter because the filter might enter a flushing
mode automatically, without prior warning.



For more information or enquiry, please contact Environmech Sdn. Bhd.
Contact us: http://www.environmech.com/p/contact-us.html 

Website: www.Environmech.com