Required Lengths of Straight Runs for Electromagnetic Flow Meter supply at Selangor (Environmech)

Required Lengths of Straight Runs for Electromagnetic Flow Meter


For optimum accuracy performance, it is required to provide sufficient inlet and outlet straight pipe runs. An equivalent to 3 diameters of straight pipe is required on the inlet side, and 2 diameters in the outlet side. There are no special requirements for standard concentric pipe reducers. See diagram 1 for required straight runs when there is an altering device.

SPECIAL NOTICE
When the meter contains removable cover plates, leave the coverplate installed unless accessory modules specify removal. Don't remove the cover plates when the meter is powered, or electrical shock and explosion hazard can be caused.

For more information or enquiry, please contact Environmech Sdn. Bhd.
Contact us: 
http://www.environmech.com/p/contact-us.html